88 research outputs found

    Nilpotent normal form for divergence-free vector fields and volume-preserving maps

    Full text link
    We study the normal forms for incompressible flows and maps in the neighborhood of an equilibrium or fixed point with a triple eigenvalue. We prove that when a divergence free vector field in R3\mathbb{R}^3 has nilpotent linearization with maximal Jordan block then, to arbitrary degree, coordinates can be chosen so that the nonlinear terms occur as a single function of two variables in the third component. The analogue for volume-preserving diffeomorphisms gives an optimal normal form in which the truncation of the normal form at any degree gives an exactly volume-preserving map whose inverse is also polynomial inverse with the same degree.Comment: laTeX, 20 pages, 1 figur

    Risk of recurrence after a first unprovoked venous thromboembolism : external validation of the Vienna Prediction Model with pooled individual patient data

    Get PDF
    Background: In order to stratify patients with a first unprovoked venous thromboembolism (VTE) according to their recurrence risk and to identify those who would actually benefit from indefinite anticoagulation, three prediction models have been developed so far; none of them has been yet externally validated. Objective: To externally validate the Vienna Prediction Model (VPM), a prediction guide for estimating the recurrence risk after a first unprovoked VTE developed through Cox modeling and including sex, D-dimer and index VTE site as predictors. Patients/Methods: Nine hundred and four patients pooled from five prospective studies evaluating the prognostic value of D-dimer for VTE recurrence served as the validation cohort. The validity of the VPM in stratifying patients according to their relative recurrence risk (discrimination) and in predicting the absolute recurrence risk (calibration) was tested with survival analysis methods. Results: The ability of the VPM to distinguish patients' risk for recurrent VTE in the validation cohort was at least as good as in the original cohort, with a calibration slope of 1.17 (95% confidence interval 0.71-1.64; P\ua0=\ua00.456 for the hypothesis of a significant difference from 1), and a c-statistic of 0.626 (vs. 0.651 in the original derivation cohort). The VPM absolute predictions in terms of cumulative rates tended to underestimate the observed recurrence rates at 12\ua0months. Conclusions: By using a pooled individual patient database as a validation cohort, we confirmed the ability of the VPM to stratify patients with a first unprovoked VTE according to their risk of recurrence

    New Results from the Cryogenic Dark Matter Search Experiment

    Full text link
    Using improved Ge and Si detectors, better neutron shielding, and increased counting time, the Cryogenic Dark Matter Search (CDMS) experiment has obtained stricter limits on the cross section of weakly interacting massive particles (WIMPs) elastically scattering from nuclei. Increased discrimination against electromagnetic backgrounds and reduction of neutron flux confirm WIMP-candidate events previously detected by CDMS were consistent with neutrons and give limits on spin-independent WIMP interactions which are >2X lower than previous CDMS results for high WIMP mass, and which exclude new parameter space for WIMPs with mass between 8-20 GeV/c^2.Comment: 4 pages, 4 figure

    Energy loss due to defect formation from 206Pb recoils in SuperCDMS germanium detectors

    Get PDF
    The Super Cryogenic Dark Matter Search experiment at the Soudan Underground Laboratory studied energy loss associated with defect formation in germanium crystals at mK temperatures using in situ 210Pb sources. We examine the spectrum of 206Pb nuclear recoils near its expected 103 keV endpoint energy and determine an energy loss of (6:08 ± 0:18)%, which we attribute to defect formation. From this result and using TRIM simulations, we extract the first experimentally determined average displacement threshold energy of 19.7+0.6−0.5 eV for germanium. This has implications for the analysis thresholds of future germanium-based dark matter searches

    PCSK9 Loss-of-Function Variants, Low-Density Lipoprotein Cholesterol, and Risk of Coronary Heart Disease and Stroke: Data from 9 Studies of Blacks and Whites

    Get PDF
    PCSK9 loss-of-function (LOF) variants allow for the examination of the effects of lifetime reduced low-density lipoprotein cholesterol (LDL-C) on cardiovascular events. We examined the association of PCSK9 LOF variants with LDL-C and incident coronary heart disease and stroke through a meta-analysis of data from 8 observational cohorts and 1 randomized trial of statin therapy. Methods and Results - These 9 studies together included 17 459 blacks with 403 (2.3%) having at least 1 Y142X or C679X variant and 31 306 whites with 955 (3.1%) having at least 1 R46L variant. Unadjusted odds ratios for associations between PCSK9 LOF variants and incident coronary heart disease (851 events in blacks and 2662 events in whites) and stroke (523 events in blacks and 1660 events in whites) were calculated using pooled Mantel-Haenszel estimates with continuity correction factors. Pooling results across studies using fixed-effects inverse-variance-weighted models, PCSK9 LOF variants were associated with 35 mg/dL (95% confidence interval [CI], 32-39) lower LDL-C in blacks and 13 mg/dL (95% CI, 11-16) lower LDL-C in whites. PCSK9 LOF variants were associated with a pooled odds ratio for coronary heart disease of 0.51 (95% CI, 0.28-0.92) in blacks and 0.82 (95% CI, 0.63-1.06) in whites. PCSK9 LOF variants were not associated with incident stroke (odds ratio, 0.84; 95% CI, 0.48-1.47 in blacks and odds ratio, 1.06; 95% CI, 0.80-1.41 in whites). Conclusions - PCSK9 LOF variants were associated with lower LDL-C and coronary heart disease incidence. PCSK9 LOF variants were not associated with stroke risk

    Commissioning and performance of the CMS pixel tracker with cosmic ray muons

    Get PDF
    This is the Pre-print version of the Article. The official published verion of the Paper can be accessed from the link below - Copyright @ 2010 IOPThe pixel detector of the Compact Muon Solenoid experiment consists of three barrel layers and two disks for each endcap. The detector was installed in summer 2008, commissioned with charge injections, and operated in the 3.8 T magnetic field during cosmic ray data taking. This paper reports on the first running experience and presents results on the pixel tracker performance, which are found to be in line with the design specifications of this detector. The transverse impact parameter resolution measured in a sample of high momentum muons is 18 microns.This work is supported by FMSR (Austria); FNRS and FWO (Belgium); CNPq, CAPES, FAPERJ, and FAPESP (Brazil); MES (Bulgaria); CERN; CAS, MoST, and NSFC (China); COLCIENCIAS (Colombia); MSES (Croatia); RPF (Cyprus); Academy of Sciences and NICPB (Estonia); Academy of Finland, ME, and HIP (Finland); CEA and CNRS/IN2P3 (France); BMBF, DFG, and HGF (Germany); GSRT (Greece); OTKA and NKTH (Hungary); DAE and DST (India); IPM (Iran); SFI (Ireland); INFN (Italy); NRF (Korea); LAS (Lithuania); CINVESTAV, CONACYT, SEP, and UASLP-FAI (Mexico); PAEC (Pakistan); SCSR (Poland); FCT (Portugal); JINR (Armenia, Belarus, Georgia, Ukraine, Uzbekistan); MST and MAE (Russia); MSTDS (Serbia); MICINN and CPAN (Spain); Swiss Funding Agencies (Switzerland); NSC (Taipei); TUBITAK and TAEK (Turkey); STFC (United Kingdom); DOE and NSF (USA)

    Alignment of the CMS silicon tracker during commissioning with cosmic rays

    Get PDF
    This is the Pre-print version of the Article. The official published version of the Paper can be accessed from the link below - Copyright @ 2010 IOPThe CMS silicon tracker, consisting of 1440 silicon pixel and 15 148 silicon strip detector modules, has been aligned using more than three million cosmic ray charged particles, with additional information from optical surveys. The positions of the modules were determined with respect to cosmic ray trajectories to an average precision of 3–4 microns RMS in the barrel and 3–14 microns RMS in the endcap in the most sensitive coordinate. The results have been validated by several studies, including laser beam cross-checks, track fit self-consistency, track residuals in overlapping module regions, and track parameter resolution, and are compared with predictions obtained from simulation. Correlated systematic effects have been investigated. The track parameter resolutions obtained with this alignment are close to the design performance.This work is supported by FMSR (Austria); FNRS and FWO (Belgium); CNPq, CAPES, FAPERJ, and FAPESP (Brazil); MES (Bulgaria); CERN; CAS, MoST, and NSFC (China); COLCIENCIAS (Colombia); MSES (Croatia); RPF (Cyprus); Academy of Sciences and NICPB (Estonia); Academy of Finland, ME, and HIP (Finland); CEA and CNRS/IN2P3 (France); BMBF, DFG, and HGF (Germany); GSRT (Greece); OTKA and NKTH (Hungary); DAE and DST (India); IPM (Iran); SFI (Ireland); INFN (Italy); NRF (Korea); LAS (Lithuania); CINVESTAV, CONACYT, SEP, and UASLP-FAI (Mexico); PAEC (Pakistan); SCSR (Poland); FCT (Portugal); JINR (Armenia, Belarus, Georgia, Ukraine, Uzbekistan); MST and MAE (Russia); MSTDS (Serbia); MICINN and CPAN (Spain); Swiss Funding Agencies (Switzerland); NSC (Taipei); TUBITAK and TAEK (Turkey); STFC (United Kingdom); DOE and NSF (USA)

    Performance of the CMS drift-tube chamber local trigger with cosmic rays

    Get PDF
    The performance of the Local Trigger based on the drift-tube system of the CMS experiment has been studied using muons from cosmic ray events collected during the commissioning of the detector in 2008. The properties of the system are extensively tested and compared with the simulation. The effect of the random arrival time of the cosmic rays on the trigger performance is reported, and the results are compared with the design expectations for proton-proton collisions and with previous measurements obtained with muon beams
    corecore